• Cooling capacity

    2.5kW

  • IT load

    1-2.5kW

  • Available IT space

    24U

  • PUE

    1.4

Features

  • Integrated design
  • Smart monitoring system
  • Free cooling system
  • Integrated design

    UPS with battery backup: 3 kVA capacity with up to 10 minutes of backup.

    Precision cooling system: 2.5 kW rack-mounted AC without an outdoor unit.

    Enclosed smart cabinet: 42U enclosed design with built-in DCIM.

    Smart monitoring system

    Monitoring: Tracking temperature, humidity, smoke, UPS, PDU and AC.

    Management: Centralizing control, diagnosing fault, asset registration and tracking assets.

    Alarm: Delivering real-time alerts via SMS, sound, phone and display.

    Uses natural cold sources for heat exchange between the free cooling module and precision AC.

    Emergency cooling: Using room air for backup during AC failure

    Mixed cooling: Combining natural cold sources with AC to save energy.

    Benefits

    • Fast deployment
      Fast deployment

      Fast deployment

      Pre-installed and pre-configured: FlexEdge comes ready to use, significantly reducing setup time.

      Cost and time savings: FlexEdge’s design minimizes installation time, labor costs and operational disruptions.

    • Space-saving design
      Space-saving design

      Space-saving design

      Integrated cooling: The system removes the need for outdoor AC units and copper piping.

      Compact cabinet: The 42U cabinet conserves space, protects equipment and simplifies maintenance.

    • Safe & reliable
      Safe & reliable

      Safe & reliable

      Comprehensive monitoring: Tracking all critical infrastructure performances with DCIM.

      Remote management: Enabling off-site system management.

      Proactive maintenance: Detecting faults early to prevent downtime.

    DataSync FlexEdge technical specifications

    Product tech specificationsFlexEdge

    Nominal cooling capacity

    2.5kW, without outdoor unit

    Free cooling system

    Operating temperature (indoor side)

    1℃—40℃

    Operating humidity RH (indoor side)

    5%-80% RH (no condensation)

    Operating altitude requirement

    Altitude<1000m (derating is required for altitudes > 1000m)

    Operating power supply

    Voltage 220V-250V, frequency:50Hz

    Height (mm)

    2000

    Width (mm)

    600

    Depth (mm)

    1000

    PDU

    2*Intelligent PDU with 2* 16A inputs and 10* C13 outputs

    UPS

    3kVA/ 2.7kW, backup time 10 mins

    DCIM system

    Displayed on standard, 10-inch touch screen

    Fire protection module

    IT space

    24U

    Accessories

    •Shelf •Blank panels •Cable management board •Background light and power