• Cooling capacity

    4kW

  • IT load

    2.5-4kW

  • Available IT space

    22U

  • PUE

    1.2

Features

  • Integrated design
  • DCIM system
  • Free cooling system
  • UPS with battery backup: 6 kVA capacity with up to 10 minutes of backup.

    Precision cooling system: 4 kW rack-mounted variable-frequency AC with an outdoor unit.

    Enclosed smart cabinet: 42U enclosed design with built-in DCIM.

    Monitoring: Tracking temperature, humidity, smoke, UPS, PDU and AC.

    Management: Centralizing control, diagnosing fault, asset registration and tracking assets.

    Alarm: Delivering real-time alerts via SMS, sound, phone and display.

    Uses natural cold sources for heat exchange between the free cooling module and precision AC.

    Emergency cooling: Using room air for backup during AC failure

    Mixed cooling: Combining natural cold sources with AC to save energy.

    Benefits

    • Energy efficiency
      Energy efficiency

      Energy efficiency

      High-efficiency AC: The 4kW variable-frequency AC is designed to minimize energy consumption.

      Mixed cooling system: The system integrates free air into the cooling process to further reduce energy usage.

    • Scalability & time saving
      Scalability & time saving

      Scalability & time saving

      Auxiliary cabinet option: Expands with up to two auxiliary cabinets for seamless IT infrastructure growth.

      Quick installation: Compared to traditional data centers, setup is much faster—only 1-2 days with copper pipe welding and outdoor unit connection.

    • Safe & reliable
      Safe & reliable

      Safe & reliable

      Comprehensive monitoring: Tracking all critical infrastructure performances with DCIM.

      Remote management: Enabling off-site system management.

      Proactive maintenance: Detecting faults early to prevent downtime.

    DataSync FlexPrime technical specifications

    Product tech specificationsFlexPrime

    Auxiliary cabinet option

    Available, max 2

    Nominal cooling capacity

    4kW

    Free cooling system

    Operating power supply

    Voltage 220V-250V, frequency:50Hz

    Height (mm)

    2000

    Width (mm)

    600

    Depth (mm)

    1200

    PDU

    2*Intelligent PDU with 12* C13 and 4* C19 output sockets, 16 ports

    UPS

    6kVA/ 5.4kW, backup time 10 mins

    DCIM system

    Displayed on standard, 10-inch touch screen

    Fire protection module

    IT space

    22U

    Accessories

    •Shelf •Blank panels •Cable management board •Background light and power •Remoted controlled door •Fingerprint recorder